Category Specification / Description
Models dBAir Safety Class 1 (GA141S), Class 2 (GA241S), Safety Octave (1/1) Class 1 (GA141ISO), Safety Octave (1/1) Class 2 (GA241ISO), Environment Octave (1/3) Class 1 (GA141EO), Safety & Environment Class 1 (1/1,1/3), Safety & Environment Class 2 (1/1,1/3) (GA141SEO)
Applicable Standards IEC 61672-1:2013, IEC 61260-1:2014 (Where Octave Bands Fitted), IEC 61252:1993 amendment 1:2000 (Where Exposure Fitted)
Microphone Class 1: Type 1 Pre-Polarised ½” (13.2mm) Electret Condenser -27±2dB re 1V/Pa; Class 2: Type 2 Pre-Polarised ½” (13.2mm) Electret Condenser -32±3dB re 1V/Pa
Measurement Range Class 1: 20–115dB (Low), 45–140dB (High); Class 2: 20–115dB (Low), 45–140dB (High)
Noise Floor Typical “A” Weighting: <15dB(A); “C” Weighting: <18dB(C); “Z” Weighting: <22dB(Z)
Frequency Range 1Hz–20kHz (electrical); Class 1: 12.5Hz–20kHz (with mic); Class 2: 16Hz–16kHz (with mic)
Frequency Weightings A, C, or Z
Time Weightings Slow, Fast, Impulse (for both measurements)
Dual Measurements Simultaneous dual measurement with independent time and frequency weightings
Octave Band Analysis Where fitted, 1/1 or 1/3 octave band analysis possible on measurement 1 only
Display 2.4″ Full Colour TFT, 240×320 pixels
Memory 16GB standard
Input/Output Connection Micro USB Type B
Power 4×AA batteries (1.5V); operation up to approx. 12–16 hours depending on settings; USB socket for data transfer
Measurement Parameters dBAir Safety: LSPL, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator.
Safety Octave: All above plus octave L values.
Environmental: All above plus environmental indices like Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, user-definable Lns
Languages English UK/US, Chinese, French, German, Italian, Portuguese, Brazilian, Russian, Spanish
Time History Short: 10ms–60m; Long: 1s–24h; options for Smart Timer, Duration, or Interval Timer
Accessories Dual level calibrator, outdoor cases, weatherproof enclosure, PSU, microphone extension cable, AC output cable
Environmental Conditions Operating: up to +50°C, storage specifics model-dependent
Physical Dimensions Including amplifier: 210mm (H) × 70mm (W) × 30mm (D); Excluding: 145mm (H) × 70mm (W) × 30mm (D); Weight: 480g (approx., with batteries)
Special Features Wi-Fi enabled for data upload; direct CSV download; voice memos; automatic calibration; SNR and HML hearing protection assessment; boundary/compliance noise; litigation support (where applicable)
Category:

Description

Integrating Sound Level Meter – dBAir Safety Series

The dBAir Safety Series from Cirrus Research provides industry-leading integrated sound level meters designed to monitor, measure, and record noise exposure in workplace and environmental settings. Combining ease of use, wide measurement capabilities, and full standards compliance, these meters support effective Condition Monitoring, occupational safety, and environmental assessments.

Key Features

  • Standards-Compliant: Meets IEC 61672-1:2013 and other relevant international standards
  • Wide Model Range: Choose from Class 1 or Class 2, with optional 1/1 and 1/3 octave band analysis
  • Smart Interface: 2.4″ color TFT display with intuitive menus and multilingual support
  • Simultaneous Dual Measurement: Independent time and frequency weighting for comprehensive analysis
  • Octave Band Functionality: Available for noise profiling and hearing protection assessment
  • Wi-Fi Enabled: Wireless data upload, direct CSV export, and voice memo capability
  • Automatic Calibration: Ensures accuracy without manual recalibration steps
  • Robust Memory & Battery: 16GB storage and up to 16 hours of operation using 4 AA batteries

Technical Specifications Overview

  • Measurement Range: 20–140 dB (Low to High)
  • Noise Floor: <15 dB(A), depending on weighting
  • Frequency Range: 1 Hz to 20 kHz (Electrical); 12.5 Hz–20 kHz (Class 1), 16 Hz–16 kHz (Class 2)
  • Frequency Weightings: A, C, Z | Time Weightings: Fast, Slow, Impulse
  • Measurement Parameters: LSPL, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Lday, Lnight, Lden
  • Data Logging: Time history from 10ms to 24h with Smart/Interval Timers
  • Memory: 16 GB internal, supports extensive data logging
  • Power Supply: 4 × AA batteries or USB, with 12–16 hours runtime
  • Dimensions: 210 × 70 × 30 mm (with amplifier) | Weight: Approx. 480g with batteries

Applications

  • Noise at Work Regulations Compliance
  • Hearing Protection Evaluation (SNR, HML, Octave Analysis)
  • Environmental Noise Assessments (Lday, Lnight, Lden, etc.)
  • Boundary Noise Monitoring & Legal Compliance
  • Litigation Support & Data Validation

Why Choose the dBAir Safety Series?

  • Versatility Across Environments: From factory floors to outdoor boundaries, dBAir adapts to your measurement needs.
  • Comprehensive Data: Captures all critical noise metrics for health & safety compliance and reporting.
  • User-Friendly Design: Lightweight, portable, and equipped with a touchscreen interface for fast deployment.
  • Digital Intelligence: Wi-Fi, cloud sync, and CSV export streamline your workflow.
  • Trusted by Professionals: Built for HSE officers, acoustic consultants, and compliance auditors.

Reviews

There are no reviews yet.


Be the first to review “Integrating Sound Level Meter – Sound Level Meter for Noise at Work – dBAir Safety”